SQ174 Pneumatic Body Massager with 5 Interchangeable Heads
The SQ174 uses adjustable pneumatic pulses for body massage. Five interchangeable heads, a touchscreen and 1–21 Hz settings make sessions easy to tailor.


SQ174 Pneumatic Shockwave Massager
A compressor-driven body massage machine that turns high-energy pneumatic pulses into precise ballistic shock waves. Five interchangeable impact heads, a touchscreen console and fully adjustable frequency and pressure cover shoulder, back, hip, leg and arm work from one compact unit.
Powered by Air, Not Vibration Motors
At the heart of the SQ174 is a built-in compressor that generates high-energy pneumatic pulses. Instead of the surface buzz of an ordinary massage gun, each pulse travels down the handle as a mechanical wave — steady, countable and adjustable strike by strike.
Transformed into Ballistic Shock Waves
Inside the handle, a bullet body is driven back and forth by the pulses, converting them into precise ballistic shock waves that travel through the impact head into the body. A thin layer of gel on the skin helps the wave couple smoothly into the tissue.
Five Impact Heads, One for Every Area
Each head threads on and off in seconds — clockwise to tighten, counter-clockwise to release. Match the head to the area: #1 small head for hands, wrists and ankles; #2 flat head for elbows and superficial muscle; #3 protruding head for knees, deep joints and soles; #4 medium head for shoulders, spine sides, waist and back; #5 large head for the back, hips and other large areas.
One-Touch Screen Control
Power on, tap the welcome screen, pick the body area, and the console suggests the right impact heads for it. Every parameter — frequency, energy, strike count — is adjusted on the same clear panel, so a new operator can get started in minutes.
Every Strike Counted and Adjustable
The function menu shows work time, a preset strike target (Preselection) and the running count (Current) — the machine prompts automatically when the target is reached. Frequency adjusts from 1 to 21 Hz, energy from 0.5 to 10.0 bar, and a lifetime counter (NUMBER OF TIMES) tracks every strike for maintenance planning.
Full-Body Massage Coverage
Shoulder, back, abdomen, hip, leg and arm — one machine covers the full body menu of a salon or home care routine. Swap heads as you move between areas and keep the head flat against the skin; the handle button only activates while the head is in contact.
A Session in Three Steps
Cleanse the skin, thread on the impact head for the area, and apply a small amount of gel if desired. Select the area on the touchscreen.
Start at the default 1 Hz and 0.5 bar, then increase frequency and energy gradually to the client's comfort.
Place the head flat on the skin, tap START on screen and press the handle button. The machine counts every strike and prompts when the preset target is done.
Maintenance reminders from the manual: empty the filter cup at the back of the machine before each use; the bullet body lasts about 2 million strikes and the system prompts automatically when it is due; replace the impact head when its dent exceeds 2 mm; pause the machine and unplug the handle cable before swapping heads.
What's in the Box
Main console × 1 · shockwave handle with control button × 1 · impact heads #1–#5 (small / flat / protruding / medium / large) · power cord × 1 · user manual × 1
Specifications
| Product Name | Pneumatic Shock Wave Massager |
| Model | SQ174 |
| Working Principle | Compressor-driven pneumatic pulses converted into ballistic shock waves |
| Frequency | 1–21 Hz (default 1 Hz) |
| Energy (Pressure) | 0.5–10.0 bar (default 0.5 bar) |
| Impact Heads | 5 interchangeable heads: #1 small / #2 flat / #3 protruding / #4 medium / #5 large |
| Display | Touchscreen LCD — work time, preset strike count, current count, total strike counter |
| Wear-Part Life | Bullet body ≈ 2 million strikes (auto prompt); bullet head ≈ 1 million; rubber pad ≈ 300,000 |
| Voltage | 110–240V, 50/60Hz |
| Device Size | 40 × 30 × 25 cm |
| Net Weight | About 9.5 kg |
| Material | ABS |
| Fuse | 10A (5 × 20 mm) |
| Plug Type | US / EU / UK / AU Plug |
| Warranty | Main unit 1 year (free service for faults under normal use) |
The device is a cosmetic beauty device, not medical equipment.
FAQ
Disclaimer & Safety Notes
Disclaimer: This is a cosmetic beauty device, not medical equipment. It is only for aesthetic body care and massage use, not for disease diagnosis or treatment. Please use it correctly and stop use once discomfort occurs. All experiences vary by individual physical condition.
Product-specific safety notes (from the user manual):
✓ Prohibited users: pregnant, lactating or menstruating women; people with implanted metal or electronic devices (cardiac pacemakers, defibrillators, nerve stimulators, drug pumps); people with malignant tumors, heart disease, arrhythmia, epilepsy, severe hypertension or diabetes; clients recovering from major surgery; areas with artificial fillers or skin wounds must be avoided.
✓ Avoid the ribs during operation. Do not work the abdomen on a full stomach — wait at least one hour after a meal. Remove all metal items from the body and clothing before a session.
✓ The handle button activates only while the impact head is in close contact with the skin. Pause the machine and unplug the handle cable before replacing heads — never aim a running handle at sensitive parts of the body.
✓ Empty the filter cup at the back of the machine before each use; accumulated water can flow back and damage the air pump. Unclog the ballistic tube every two days with a brush dipped in lubricating oil.
✓ Leave at least 5 cm of space around the machine for ventilation; operate at 0–26 °C and below 80% relative humidity. Power off and unplug before replacing the 10A fuse. Do not use near short-wave or microwave equipment (keep at least 1 meter away).
International mains compatibility: 110–240 V AC.